The rotary distribution structure is adopted, which runs smoothly, overcomes the defects of reciprocating distribution structure and enhances the measurement reliability;
The rotation is stable and never leaks, thus ensuring the safety performance of the product; The rotation of the movement transmission mechanism is transmitted to the counter outside the shell through magnetic force, ensuring accurate measurement, stable performance and good consistency of repeated detection; The internal control indication error index is ± 1%, which can ensure that the detection in different regions can be qualified.
The surface of the shell is treated with plastic spraying, which has bright color, beautiful appearance and good corrosion resistance. It is designed with a variety of structures and devices to prevent external interference and damage.
Features
- High measurement accuracy. The movement redesigns the rotating volume, and the difference between the diaphragm volume and the standard volume is less than 10%, so the change of the rotating volume will be very small within the size error range of each part, improve the accuracy of measurement.
- High stability and good consistency of repeat detection. Unique diaphragm limit and forced diaphragm turnover device is adopt.The limit of each movement of the diaphragm is at the same position, so that each movement of the diaphragm is filled with the same amount of gas, even after multiple movements and testing, the error of multiple detection is greatly reduced, and the stability of the meter and the consistency of repeated detection are improved.
- Good durability. The low-temperature diaphragm is adopted, and has very good softness, and will not deform after multiple operations, so that the rotation volume will not change too much, and the durability of the meter is greatly improved.
HKT provides customized services
- ODM
- Pre-sales & After-sales Services
- Technology Support
Product Specifications
Parameters | Description | ||
The performance parameters | G1.6 | G2.5 | G4 |
Length | 165mm | 195mm | 225mm |
Minimum Flow (Q1 (m³/h)) | 0.016 | 0.025 | 0.04 |
Startup flow (Q2 (m³/h)) | 0.05 | 0.08 | 0.126 |
Maximum Flow (Q3 (m³/h)) | 2.5 | 4 | 6.3 |
Communication | Standard LoRaWAN Protocol |
Cyclotron volume (Vc) | 1.2dm3 |
Maximum allowable error | (0.1qmax ≤ q ≤ qmax) ±1.5% (qmin ≤ q ≤ 0.1qmax) ±3% |
Maximum working pressure | ≤50kPa |
Pressure loss | ≤200kPa |
Sealing | 75 kPa hold pressure for 3 minutes without leakage |
Durability | Run for 2000 hours, meet the above performance indicators |
Ambient Temperature Range | -10 ℃ to 40 ℃ |
Center distance of meter joint | 130mm |
Joint Screw | M30*2mm |
External connection screw thread | DN15 |
Product size | 203mm x 130mm x 225mm |
Weight | 2 Kg |
MOQ | 50 SQM |
NRC | 0.88 from ISO354 |
Fire protection performance | Class A |
Eco-Friendly | E1 |
Dimensions

Packing list
- 1x Membrane gas meter
- 2x Coupling and sealing washer (optional)